Bulk Reagents for CLIA

Cnpair provides reliable bulk reagents for chemiluminescence immunoassay (CLIA) . Our materials are optimized for high sensitivity, low background, and excellent stability, meeting the requirements of automated CLIA platforms. Through strong R&D capabilities and scalable manufacturing, Cnpair supports global partners in developing high-quality diagnostic products.

antibody antigen

Bulk Reagents for CLIA

ClassificationProduct NameCat.Application
Sexually Transmitted DiseaseHIV-Ab-AE bulk set301622Acridinium ester
HIV-P24-AE bulk set301239Acridinium ester
HIV-1-AE bulk set301139Acridinium ester
HIV-2-AE bulk set301140Acridinium ester
HIV-Ab/Ag-AE bulk set301137Acridinium ester
HBcAb-AE bulk set(Competition method)205421Acridinium ester
HBcAb-AE bulk set(Indirect method)205877Acridinium ester
HBsAg-AE bulk set205351Acridinium ester
HBeAg-AE bulk set205619Acridinium ester
HCV-AE bulk set210800Acridinium ester
HCV-AE bulk set210798Acridinium ester
TP-AE bulk set(Chimeric Ag+Single Fragments)211038Acridinium ester
TP-AE bulk set(Chimeric Ag+Chimeric Ag)211042Acridinium ester

FAQ

What is an acridinium ester (AE) bulk set, and why is AE labeling used in CLIA?

An acridinium ester bulk set supplies the core immunoreagents for AE-based chemiluminescence immunoassay in bulk quantities, intended for automated CLIA platforms. AE is a direct chemiluminescent label: it emits light on chemical oxidation without an enzyme intermediate, which gives fast signal generation, high sensitivity, low background, and a wide dynamic range. These properties, together with reagent stability, are why AE formats dominate high-throughput automated immunoassay systems.

Cnpair offers acridinium ester bulk sets covering the main sexually transmitted disease markers: HIV-Ab (301622), HIV-P24 (301239), HIV-1 (301139), HIV-2 (301140), HIV-Ag/Ab combo (301137), HBcAb in both competitive (205421) and indirect (205877) formats, HBsAg (205351), HBeAg (205619), HCV (210800 and 210798), and TP in two antigen designs — chimeric antigen plus single fragments (211038) and chimeric antigen plus chimeric antigen (211042).

The two HBcAb bulk sets reflect different assay architectures: the competitive method (205421) is built around signal reduction on binding, while the indirect method (205877) uses a secondary detection step, so the choice depends on your platform’s workflow, dynamic range requirements, and existing calibration logic. For TP, both designs use chimeric antigens to reduce non-specific binding, and differ in pairing — chimeric antigen plus single fragments (211038) or chimeric antigen plus chimeric antigen (211042) — so selection should follow the sensitivity and specificity balance your syphilis assay needs.

Related Posts

Blocking Reagent
Cnpair Blocking Agents: Reducing False Results from Antibody Interference

Online Inquiry